首页 > 最新目录 > 正文

24 .H型钢部分包裹混凝土组合柱弱轴方向偏压性能试验研究

日期:2016-08-29 19:41:51 点击:

赵根田,朱宇,胡鳅文

(内蒙古科技大学建筑与土木工程学院,内蒙古包头 014010

关键词:H型钢;部分包裹混凝土;弱轴方向;偏心受压

中图分类号:TU398.9         文献标识码:A

要:本文对7PEC柱进行了弱轴方向偏心受压试验,主要考虑了翼缘宽厚比和偏心距这两种因素的影响。试验结果表明:随着偏心距的增大,偏心受压构件的极限承载能力降低;随着翼缘

宽厚比的减小,偏压构件的极限承载能力有所提高;偏心距对构件的极限承载能力影响较大

Experimental study on H steel partiallyencased composite column weak axisdirection eccentricity compression performance

ZHAO Gen-tian ,ZHU Yu,HU Qiu-wen

( Architecture and Civil Engineering School, Inner Mongolia University of Science and Technology , Baotou 014010, China)

Key words: partially encased concrete; short composite column; load bearing capacity

Abstract: Eccentricity compression test on 7 welding H steel partially encased concrete composite columns in weak axis were studied, mainly considering the effect of flange width thickness ratio and eccentric distance. The results showed that with the increase of eccentricity, the ultimate bearing capacity of eccentric compression member decreased; with the decrease of the flange width thickness ratio, the limit of bearing capacity of eccentrically compressed members increased; and the eccentricity had a greater influence on the ultimate bearing capacity of the components.

地址:内蒙古包头市昆都仑区阿尔丁大街7号 邮编:014010 电话:0472-5951610或0472-5953910 Email:cky@imust.edu.cn nkdxb@imust.edu.cn

版权所有:内蒙古科技大学学报编辑部(©2013)